产品说明
一般描述
PAHs in Soil - PT proficiency testing material is produced in accordance with ISO/IEC 17043:2010. This product is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well.
Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. We are the world leader in the manufacturing of real-world soil and sediment PT products. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.
Type of PT Scheme: Solids/Soils Hazardous Waste
Matrix: Soil
Analyte/s: Values of analytes vary lot to lot.
All information regarding the use of PAHs in Soil - PT can be found in the reporting packet which will be available to download at PT Portal.
应用
PAHs in Soil - PT is a soils/hazardous waste proficiency testing material, suitable for testing PAHs in soil samples.
Our soil PT samples behave as real samples; and, unless there is no alternative, are not simply spikes added to a blank soil. They are designed to meet the requirements of national, regional and state-specific accreditation bodies (TNI, USEPA, UKAS) for quality assurance and continuous improvement.
Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.
特点和优势
We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.
Our proficiency testing (PT) program is a benchmark to:
- provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
- provide a comparison of performance with that of other laboratories, nationally and internationally
- test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
- provide an independent evaluation of laboratory performance
- demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality
制备说明
Description
- This product consists of 4 vials, each containing 10 g of soil for analysis of PAHs. Each vial is identical and has been tested to show homogeneity. Only one vial is needed for the test. The remaining vials are to be used for multiple methods or routine testing.
- Four samples have been provided for your convenience (multiple methods, multiple analysts, etc.)
- The soil has been chemically stabilized with 1 mL of acetone to minimize degradation of the sample.
- The evaluation of results will be based on study statistics as required by TNI.
- This standard may not contain all the compounds listed on the Report Forms in accordance with TNI standards. For analytes not detected, report a zero or a ‘<′ ′ and your detection limit.
- Store sample at room temperature. Once opened sample should be used within 3 months or by the expiration date on the label, whichever is sooner.
Sample Preparation
- Extract the complete contents of a single vial. Transfer entire contents of one vial to extraction vessel. Rinse vial and cap with extraction solvent.
- Note: Sample extracts and calibration solutions should be in the same solvent.
- Analyze the Extract using the appropriate Semi-Volatile Organics method for which you are seeking accreditation.
- Determine the concentration of the analytes listed and report your results on the organic analysis data sheet provided.
- The method used must be reported.
- Report all results on a wet weight basis, do not correct for moisture.
- Assume a 10 g sample size for all calculations.
储存及稳定性
Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
其他说明
Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.
When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.
Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.
Proficiency Testing Schedule (2021-2022)
Soils
LPTP21-S2April 7 - May 21, 2021
LPTP21-S4 October 6 - November 19, 2021
LPTP22-S2April 6 - May 20, 2022
LPTP22-S4 October 5 - November 18, 2022
法律信息
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
基本信息
NACRES | NA.24 |
产品性质
质量水平 | 100 |
包装 | pkg of 1 × 40 g |
基质 | soil |
application(s) | environmental |
格式 | matrix material |
安全信息
危险声明 | H412 |
预防措施声明 | P273 - P501 |
危险分类 | Aquatic Chronic 3 |
储存分类代码 | 13 - Non Combustible Solids |
WGK | WGK 1 |
闪点(F) | Not applicable |
闪点(C) | Not applicable |