产品说明
一般描述
Volatile Residue - WP proficiency testing material is produced in accordance with ISO/IEC 17043:2010. Also referred to as non-Potable water or Water Pollution sample, this sample is produced according to TNI requirements. However, please note, this sample may include non-TNI analytes as well. The higher criteria from the TNI tables mimic the levels common to wastewater samples. The PT portfolio allows our test components to offer significant performance data to monitor and prove competency to customers, accreditation bodies or both.
Supelco® is a global proficiency testing (PT) provider that manufactures best-in-class environmental and pharmaceutical PT products. Most water PT samples are available as concentrates or ready-to-use volumes giving the end-user flexibility in selecting samples that will fit their exact needs. Our WP program is designed to meet the quality assurance requirements, thereby ensuring the analytical competence of your laboratory.
Type of PT Scheme: Water analysis - Water Pollution (WP)
Matrix: Water Pollution/Wastewater
Analyte/s: Values of analytes vary lot to lot.
All information regarding the use of Volatile Residue - WP can be found in the reporting packet which will be available to download at PT Portal.
应用
Volatile Residue - WP is a non-Potable water (NPW) PT standard, suitable for testing volatile solids in water pollution/wastewater.
Have any questions? Explore our FAQs.
For more information on this product, please contact our PT Service Team.
特点和优势
We have a vast portfolio of environmental PT schemes with "fit-for-purpose" samples to help you meet the needs of the laboratory.
Our proficiency testing (PT) program is a benchmark to:
- provide staff with an insight into their laboratory′s performance, to verify the accuracy and reliability of their testing process
- provide a comparison of performance with that of other laboratories, nationally and internationally
- test and educate staff, provide a better understanding of the impact of incorrect results and identify areas where there may be problems
- provide an independent evaluation of laboratory performance
- demonstrate to clients, colleagues and accreditation bodies that there is a commitment to quality
制备说明
Description
- This PT sample is a concentrate for dilution in DI water.
- The solvent for this sample is NaCl.
- The sample must be stored at room temperature.
Sample Preparation
- Partially fill a 1000 mL volumetric flask with reagent-grade water.
- Open vial PE1091-1.2G and weigh 500 mg of solids and quantitatively transfer to the volumetric flask using a glass funnel.
- Fill the volumetric flask to volume (1000 mL) and mix by inverting the flask 10 times.
- Let the flask stand for 10 min and invert again 10 times.
- The sample is now ready for immediate analysis.
- Do not filter the sample prior to volatile analysis. Analyte losses may occur.
储存及稳定性
Please refer to sample label for expiration date, specific storage temperature, and specific storage conditions.
其他说明
Are you new to Supelco® Proficiency Testing? Be sure to register your account details in the PT Portal before placing your order.
This will provide access to data entry, reporting packets and final reports. Registrations will be approved shortly after your order is placed. For further questions, write to us at ptservice@milliporesigma.com.
When placing your order online, please indicate your study preference under the ′your reference′ column. Available studies can be viewed at the bottom of the page.
Click here to learn more about Quick-Turn Studies (on-demand proficiency tests that are offered depending on lot availability). The Quick-Turn results are released within 48-72 hours whereas scheduled study reports are released within 21 days.
Proficiency testing samples are presented as single blind. No values for the samples are released until the testing period concludes.
Proficiency Testing Schedule (2021-2022)
Wastewater
WP21-2March 24 - May 7, 2021
WP21-4September 22 - November 5, 2021
WP22-2March 23 - May 6, 2022
WP22-4September 21 - November 4, 2022
法律信息
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
基本信息
NACRES | NA.24 |
产品性质
质量水平 | 100 |
包装 | ampule of 1 × 1.2 g |
基质 | NaCl |
application(s) | environmental |
格式 | matrix material |
安全信息
象形图 | |
警示用语: | Warning |
危险声明 | H319 - H335 |
预防措施声明 | P261 - P305 + P351 + P338 |
危险分类 | Eye Irrit. 2 - STOT SE 3 |
靶器官 | Respiratory system |
储存分类代码 | 12 - Non Combustible Liquids |
WGK | WGK 3 |
闪点(F) | Not applicable |
闪点(C) | Not applicable |