产品说明
一般描述
The MAS-100 ISO MH® control unit, 2 heads is designed to monitor the microbial contamination of the air in isolators and RABS but can also be used as fixed point sampling in cleanrooms. Like all other MAS-100 air samplers, it′s based on the Andersen impaction principle. The control unit with electronic and moving blower parts can be located outside the critical zone, while the single sampling head for standard 90 to 100 mm Petri dishes collect samples in the containment zone. The tubing length can be up to 10m when used with VHP decontamination or up to 50m without. The innovative double valve system enables the sampling heads to be integrated into the decontamination process with VHP. Each unit has both an air and a sterilization pump that operate autonomously.
The fully automatic calibration of the device guarantees maximum efficiency and accuracy. The system measures the air flow and regulates it to a constant value of 100 liters/min. These systems have the highest airflow accuracy of ±2.5%, compared to others that can be as high as ±10%. The instruments are designed and built according to GAMP 5 and are independently validated according to ISO 14698-1 with very good physical efficiency providing a D50 value below 1.1μm and a high biological efficiency result. The efficiencies and the D50 values are independent of the tube length and are comparable to the other members of the MAS-family.
This version is equipped with two valves for two sampling heads and RS232, USB and digital IN/OUT interfaces for communication. In case other communication interfaces are required, two alternative models of either MAS-100 ISO MH® Control unit with Ethernet, 2 heads with Ethernet interface or MAS-100 ISO MH® Control unit with Profibus, 2 heads with Profibus interface are available.
The type of sample base (standard or easy clean version) as well as the perforated lids can be selected separately according to the specific needs of the sample location and workflow.
应用
MAS-100 ISO MH® Control unit, 2 heads is suitable for microbial monitoring in isolators and RABS. The microbial air sampling devices are extensively used in Pharmaceutical applications.
组分
Control unit equipped with two valve connections (incl. cables) for two sampling heads, a range of phoenix connectors, USB cable, digital I/O, USB stick with all manuals and documentation.
法律信息
MAS-100 ISO MH is a registered trademark of MBV AG
产品性质
物料 | aluminum hardware |
agency | according to ISO 14698 |
特点 | calibrated to deliver model (installed) |
包装 | pkg of 1 kit |
manufacturer/tradename | MAS-100 Iso MH® |
application(s) | air monitoring pharmaceutical |
储存温度 | no temp limit |
安全信息
储存分类代码 | 10-13 - German Storage Class 10 to 13 |